Tee Pattern Strain Gages: Multiple Sensors - One Backing
They are used where direct tension measurements are desired, such as a bolt in tension or a suspension rod in compression. A full bridge in this situation minimises pickup due to bending. Tee rosettes can also be deployed for bending measurements, which is especially useful on large infrastructures such as wind turbine towers.
Adjacent gauges on the same backing will see identical temperatures and therefore eliminate thermal outputs due to differential temperatures across the structure. Additionally, 45° alignment marks are provided on each T-Rosette gage so it may be accurately applied to a shaft to measure torsion. Refer to TechNote 515.
CEA Series Tee Rosette Strain Gages |
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[in/mm] | [in/mm] | [in/mm] | [in/mm] | |||||||||||||||
Configuration
|
Pattern | Res. [Ω] |
Gage Length |
Gage Width |
Matrix Length |
Matrix Width |
Standard STC |
Temperature Range |
Options | |||||||||
Tee Rosette Strain Gage | 062UTA |
120, 350 |
0.062 [1.57] |
0.080 [2.03] |
0.31 [7.9] |
0.31 [7.9] |
00, 03, 05, 06, 09, 13 |
–100° to +350°F (–75° to +175°C) |
P2, SP11 |
|||||||||
125UTA |
120, 350 |
0.125 |
0.165 |
0.42 |
0.45 |
|||||||||||||
250UTA |
120, 350 |
0.250 |
0.290 |
0.48 [12.19] |
0.40 [10.16] |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||
Stacked Tee Rosette Strain Gage | 032WT | 120 |
0.032 |
0.060 |
0.30 |
0.30 |
||||||||||||
062WT |
120, 350 |
0.062 [1.57] |
0.120 [3.05] |
0.33 [8.4] |
0.33 [8.4] |
|||||||||||||
125WT |
120, 350 |
0.125 [3.18] |
0.180 [4.57] |
0.42 [10.7] |
0.42 [10.7] |
|||||||||||||
250WQ |
350 |
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||
Temperature Range | ||||||||||||||||||
Typically used with: | M-Bond 200 Kit | Room temperature instant curing strain gage adhesive | –25° to +150°F (–30° to + 65°C) | |||||||||||||||
M-Bond AE-10 Kit | Two-component, 100%-solids epoxy system for general purpose strain gages Room temperature cure, highly resistant to moisture and most chemicals |
–320° to +400°F (–195° to +204°C) | ||||||||||||||||
M-Bond 600 Kit | Two-component, solvent-thinned, epoxy-phenolic strain gage adhesive for high-performance | –452° to +500°F (–268° to +260°C) | ||||||||||||||||
EA Series Tee Rosette Strain Gages |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[in/mm] | [in/mm] | [in/mm] | [in/mm] | |||||||||||||||
Configuration | Pattern | Res. [Ω] |
Gage Length |
Gage Width |
Matrix Length |
Matrix Width |
Standard STC | Temperature Range | Options | |||||||||
Tee Rosette Strain Gage | 030TU | 120 |
0.030 [0.76] |
0.044 [1.12] |
0.25 [6.4] |
0.25 [6.4] |
00, 03, 05, 06, 09, 13 |
–100° to +350°F (–75° to +175°C) |
E, EL, P, W, SP11 |
|||||||||
030TY | 120 |
00.030 [0.76] |
0.044 [1.12] |
0.30 [7.6] |
0.15 [3.8] |
|||||||||||||
050TGA | 350 |
0.050 [1.27] |
0.070 [1.78] |
0.34 [8.6] |
0.17 [4.3] |
|||||||||||||
062TJA | 350 |
0.062 [1.57] |
0.080 [2.03] |
0.38 [9.7] |
0.19 [4.8] |
|||||||||||||
062TTA |
120, 350 |
0.062 [1.57] |
0.075 [1.91] |
0.28 [7.1] |
0.26 [6.6] |
|||||||||||||
062TZA |
350 |
0.062 [1.57] |
0.075 [1.91] |
0.28 [7.1] |
0.26 [6.6] |
|||||||||||||
125TB | 350 |
0.125 [3.18] |
0.150 [3.81] |
0.36 [9.1] |
0.44 [11.2] |
|||||||||||||
125TG | 350 |
0.125 [3.18] |
0.150 [3.81] |
0.59 [15.0] |
0.21 [5.3] |
|||||||||||||
250TM |
120 , 350 |
0.250 [6.35] |
0.300 [7.62] |
0.53 [13.5] |
0.75 [19.1] |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||
Temperature Range | ||||||||||||||||||
Typically used with: | M-Bond 200 Kit | Room temperature instant curing strain gage adhesive | –25° to +150°F (–30° to + 65°C) | |||||||||||||||
M-Bond AE-10 Kit | Two-component, 100%-solids epoxy system for general purpose strain gages Room temperature cure, highly resistant to moisture and most chemicals |
–320° to +400°F (–195° to +204°C) | ||||||||||||||||
Two-component, solvent-thinned, epoxy-phenolic strain gage adhesive for high-performance |
–452° to +500°F (–268° to +260°C) | |||||||||||||||||
WK Series Tee Rosette Strain Gages |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[in/mm] | [in/mm] | [in/mm] | [in/mm] | |||||||||||||||
Configuration | Pattern | Res. [Ω] |
Gage Length |
Gage Width |
Matrix Length |
Matrix Width |
Standard STC | Temperature Range | Options | |||||||||
Tee Rosette Strain Gage | 062TT | 350 |
0.062 [1.57] |
0.075 [1.91] |
0.28 [7.1] |
0.26 [6.6] |
00,03,05, 06,09,13 |
–452° to +550°F (–269° to +290°C) |
W, SP11 |
|||||||||
125TB | 1000 |
0.125 [3.18] |
0.150 [3.81] |
0.36 [9.1] |
0.44 [11.2] |
|||||||||||||
125TM | 350 |
0.125 [3.18] |
0.150 [3.81] |
0.36 [9.1] |
0.43 [10.9 |
|||||||||||||
125TQ | 1000 |
0.125 [3.18] |
0.150 [3.81] |
0.42 [10.7] |
0.47 [11.9] |
|||||||||||||
250TB | 1000 |
0.250 [6.35] |
0.300 [7.62] |
0.63 [16.0] |
0.81 [20.6] |
|||||||||||||
250TM | 350 |
0.250 [6.35] |
0.300 [7.62] |
0.53 [13.5] |
0.75 [19.1] |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Temperature Range | ||||||||||||||||||
Typically used with: | M-Bond 200 Kit | Room temperature instant curing strain gage adhesive | –25° to +150°F (–30° to + 65°C) | |||||||||||||||
M-Bond AE-10 Kit | Two-component, 100%-solids epoxy system for general purpose strain gages Room temperature cure, highly resistant to moisture and most chemicals |
–320° to +400°F (–195° to +204°C) | ||||||||||||||||
M-Bond 600 Kit | Two-component, solvent-thinned, epoxy-phenolic strain gage adhesive for high-performance | –452° to +500°F (–268° to +260°C) | ||||||||||||||||
C2A Series Tee Rosette Strain Gages |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[in/mm] | [in/mm] | [in/mm] | [in/mm] | |||||||||||||||
Configuration | Pattern | Res. [Ω] |
Gage Length |
Gage Width |
Matrix Length |
Matrix Width |
Standard STC | Temperature Range | Options | |||||||||
Gages With Pre-attached Cables | 062LT | 120 , 350 |
0.062 [1.57] |
0.070 [1.78] |
0.21 [5.3] |
0.29 [7.4] |
06, 09, 13 |
–60° to +180°F (–50° to +80°C) |
|
|||||||||
125LT | 120 , 350 |
0.125 [3.18] |
0.150 [3.81] |
0.29 [7.4] |
0.40 [10.2] |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||||
Temperature Range | ||||||||||||||||||
Typically used with: | M-Bond 200 Kit | Room temperature instant curing strain gage adhesive | –25° to +150°F (–30° to + 65°C) | |||||||||||||||
M-Bond AE-10 Kit | Two-component, 100%-solids epoxy system for general purpose strain gages Room temperature cure, highly resistant to moisture and most chemicals |
–320° to +400°F (–195° to +204°C) | ||||||||||||||||
M-Bond AE-15 Kit | Two-component, 100%-solids epoxy system for general purpose strain gages Room temperature cure, highly resistant to moisture and most chemicals |
–320° to +200°F (–195° to +95°C) | ||||||||||||||||
VIDEOS
Explore our extensive collection of tutorials and informational videos on a variety of strain measurement topics.
STRAINTALKS
Explore our free education seminars aimed at helping Design and Test Engineers understand strain gage theory selection, preparation, performance, installation, configuration, and more.
STRAINBLOG
Questions and answers on the go! Listen to Micro-Measurements experts explain the many facets of strain gage technology.
TRAINING
Benefit from an extensive series of regularly scheduled, hands-on technical workshops and short courses.